Quality indicators for blood culture: three years of monitoring at a university hospital in Chile

dc.contributor.authorMaria Guzman, Ana
dc.contributor.authorSanchez, Tomas
dc.contributor.authorde la Barra, Ricardo
dc.date.accessioned2024-01-10T12:41:54Z
dc.date.available2024-01-10T12:41:54Z
dc.date.issued2012
dc.description.abstractBlood culture is considered the "gold standard" for the diagnosis of bacteremia, critical condition with high morbidity and mortality. Because of its importance, it is estimated that the blood culture is a critical test that requires close monitoring on the quality with which the process is performed. The objective of this work is to show the results of the monitoring carried out during the past three years, of 5 quality indicators of blood cultures in the laboratory of the Hospital Clinico de la Pontificia Universidad Catolica de Chile, considering pre-analytical, analytical and post-analytical aspects. In the 3 years monitored the mean contamination was 0,7%, 46% of adult bottles had adequate volume, match between Gram stain with final identification was 99.4%, 100% of correct participations were achieved in surveys of external quality control and Gram staining notification before 1 hour was 88.7%. With regard to proposed aims, in 2011 the laboratory complies with all, except the percentage of bottles with appropriate volume of blood inoculated. This indicator is very low and should be corrected as soon as possible since it is known that it is an important condition for optimum performance of blood cultures.
dc.fechaingreso.objetodigital2024-05-30
dc.format.extent6 páginas
dc.fuente.origenWOS
dc.identifier.doi10.4067/S0716-10182012000400007
dc.identifier.issn0716-1018
dc.identifier.pubmedidMEDLINE:23096540
dc.identifier.urihttps://doi.org/10.4067/S0716-10182012000400007
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/77462
dc.identifier.wosidWOS:000307987100007
dc.information.autorucMedicina;De la Barra R;S/I;116959
dc.information.autorucMedicina;Guzman A;S/I;117075
dc.information.autorucMedicina;Sanchez T;S/I;117554
dc.issue.numero4
dc.language.isoes
dc.nota.accesoContenido completo
dc.pagina.final411
dc.pagina.inicio406
dc.publisherSOC CHILENA INFECTOLOGIA
dc.revistaREVISTA CHILENA DE INFECTOLOGIA
dc.rightsacceso abierto
dc.subjectQuality indicators
dc.subjectblood cultures
dc.subjecthealthcare
dc.subjectGRAM STAIN
dc.subjectCONTAMINATION
dc.subjectINSTITUTIONS
dc.subjectBOTTLES
dc.subject.ods03 Good Health and Well-being
dc.subject.odspa03 Salud y bienestar
dc.titleQuality indicators for blood culture: three years of monitoring at a university hospital in Chile
dc.typeartículo
dc.volumen29
sipa.codpersvinculados116959
sipa.codpersvinculados117075
sipa.codpersvinculados117554
sipa.indexWOS
sipa.indexScielo
sipa.indexScopus
sipa.trazabilidadCarga SIPA;09-01-2024
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Quality indicators for blood culture; three years of monitoring at a university hospital in Chile.pdf
Size:
193.23 KB
Format:
Adobe Portable Document Format
Description: