High-resolution 3D whole-heart bright- and black-blood imaging with co-registered T2 mapping at 0.55 T

dc.article.number1572318
dc.catalogadorvdr
dc.contributor.authorKokhanovskyi, Ivan
dc.contributor.authorCastillo Passi, Carlos
dc.contributor.authorCrabb, Michael G.
dc.contributor.authorGanter, Carl
dc.contributor.authorLittlewood, Simon J.
dc.contributor.authorKunze, Karl P.
dc.contributor.authorKarampinos, Dimitrios C.
dc.contributor.authorMakowski, Marcus R.
dc.contributor.authorRueckert, Daniel
dc.contributor.authorPrieto Vásquez, Claudia
dc.contributor.authorBotnar, René Michael
dc.date.accessioned2025-08-30T11:01:43Z
dc.date.available2025-08-30T11:01:43Z
dc.date.issued2025
dc.description.abstractConventional CMR exams for assessment of cardiac anatomy and tissue characterization require multiple sequential 2D acquisitions under breath-hold in different orientations, in addition to being limited to 1.5 T and 3 T. Methods: In this study, we sought to develop a novel 3D motion-compensated free-breathing sequence for comprehensive high-resolution whole-heart assessment of cardiovascular anatomy via simultaneous bright- and black-blood imaging and co-registered (Formula presented.) myocardial tissue quantification in a one-click scan at 0.55 T. Results: Good agreement with a spin-echo reference sequence was found in the phantom for (Formula presented.) mapping. In-vivo, the proposed research sequence was evaluated in 10 healthy subjects, providing great delineation of cardiac and vascular structures, good visibility of coronary arteries and accurate (Formula presented.) parametric mapping in a clinically feasible time of less than 9 min.
dc.description.funderFONDECYT; Folios: 1250261, 1250252
dc.format.extent10 páginas
dc.fuente.origenScopus
dc.identifier.doi10.3389/fcvm.2025.1572318
dc.identifier.eissn1550-9613
dc.identifier.issn2297-055X
dc.identifier.scopusidSCOPUS_ID:105010958397
dc.identifier.urihttps://doi.org/10.3389/fcvm.2025.1572318
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/105479
dc.identifier.wosidWOS:001510704800001
dc.information.autorucEscuela de Ingeniería; Castillo Passi, Carlos; 0000-0001-6227-0477; 204150
dc.information.autorucEscuela de Ingeniería; Prieto Vásquez, Claudia; 0000-0003-4602-2523; 14195
dc.information.autorucEscuela de Ingeniería; Botnar, René Michael; 0000-0003-2811-2509; 1015313
dc.issue.numero2
dc.language.isoen
dc.nota.accesoContenido completo
dc.pagina.final10
dc.pagina.inicio1
dc.publisherCambridge University Press
dc.relation.ispartof21st Annual Conference of the International-Society-for-Environmental-Epidemiology, AUG 25-29, 2009, Dublin, IRELAND
dc.revistaFrontiers in Cardiovascular Medicine
dc.rightsacceso abierto
dc.subject3D whole-heart
dc.subjectHigh-resolution coronary angiography
dc.subjectLow-field MRI
dc.subjectSimultaneous bright-and black-blood
dc.subjectT2 mapping
dc.subject.ddc610
dc.subject.deweyMedicina y saludes_ES
dc.subject.ods03 Good health and well-being
dc.subject.odspa03 Salud y bienestar
dc.titleHigh-resolution 3D whole-heart bright- and black-blood imaging with co-registered T2 mapping at 0.55 T
dc.typeartículo
dc.volumen12
sipa.codpersvinculados204150
sipa.codpersvinculados14195
sipa.codpersvinculados1015313
sipa.indexScopus
sipa.trazabilidadWOS-SCOPUS;2025-08-30
Files