Five-year Effects of Chlorhexidine on the In Vitro Durability of Resin/Dentin Interfaces
dc.contributor.author | Loguercio, A. D. | |
dc.contributor.author | Hass, V. | |
dc.contributor.author | Gutierrez, M. F. | |
dc.contributor.author | Luque Martínez, Íssis Virginia | |
dc.contributor.author | Szezs, A. | |
dc.contributor.author | Stanislawczuk, R. | |
dc.contributor.author | Bandeca, M. C. | |
dc.date.accessioned | 2019-10-16T20:16:10Z | |
dc.date.available | 2019-10-16T20:16:10Z | |
dc.date.issued | 2016 | |
dc.description.abstract | Purpose: To evaluate the effect of an acid containing 2% chlorhexidine (Ac/CHX) or a 2% CHX aqueous solution (Aq/CHX) on the immediate and 5-year bonding properties of resin/dentin interfaces produced by two adhesives. The presence of CHX in these interfaces was also evaluated under micro-Raman spectroscopy. Materials and Methods: Forty-two molars were ground to expose a flat dentin surface. In the control group, the surfaces were etched with conventional phosphoric acid, and Prime&Bond NT (PB) and Adper Single Bond 2 (SB) were applied. In Ac/CHX, an acid containing 2% CHX was applied after adhesive application. In the Aq/CHX group, an aqueous solution of 2% CHX was applied for 60 s after etching. After placing the restoration, specimens were prepared and tested using the microtensile bond strength test (mu TBS, 0.5 mm/min) immediately or after 5 years. For nanoleakage (NL), specimens at each period were immersed in silver nitrate solution and examined by EDX-SEM. In addition, specimens at each period underwent examination for CHX using micro-Raman spectroscopy. Data were submitted to appropriate statistical analysis (alpha = 0.05). Results: After 5 years, NL was more pronounced in the control than in the Ac/CHX or Aq/CHX (p < 0.001). Significant reductions in the mu TBS were observed for all groups; however, they were more pronounced for the control (p < 0.001). CHX was still present in the hybrid layers Ac/CHX or Aq/CHX groups after 5 years. Conclusion: The use of a 2% chlorhexidine-containing acid or the application of an aqueous CHX primer may increase the long-term stability of resin/dentin interfaces. | |
dc.format.extent | 8 páginas | |
dc.fuente.origen | Facultad de Medicina | |
dc.identifier.doi | 10.3290/j.jad.a35514 | |
dc.identifier.issn | 1461-5185 | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/26565 | |
dc.identifier.wosid | WOS:000370793500004 | |
dc.issue.numero | No. 1 | |
dc.language.iso | en | |
dc.nota.acceso | Contenido parcial | |
dc.pagina.final | 42 | |
dc.pagina.inicio | 35 | |
dc.revista | Journal of Adhesive Dentistry | es_ES |
dc.rights | acceso restringido | |
dc.subject | adhesive systems | es_ES |
dc.subject | chlorhexidine | es_ES |
dc.subject | water sorption | es_ES |
dc.subject | nanoleakage | es_ES |
dc.subject | microtensile bond strength | es_ES |
dc.subject | longevity | es_ES |
dc.subject | resin-dentin interfaces | es_ES |
dc.subject | matrix metalloproteinases | es_ES |
dc.subject | bond strength | es_ES |
dc.subject | clinical-performance | es_ES |
dc.subject | collagen degradation | es_ES |
dc.subject | cysteine cathepsins | es_ES |
dc.subject | rinse | es_ES |
dc.subject | adhesives | es_ES |
dc.subject | containing acid | es_ES |
dc.subject | mmp inhibitors | es_ES |
dc.subject | nanoleakage | es_ES |
dc.subject | Dentistry, Oral Surgery & Medicine | es_ES |
dc.subject.ddc | 610 | |
dc.subject.dewey | Medicina y salud | es_ES |
dc.subject.ods | 03 Good health and well-being | |
dc.subject.odspa | 03 Salud y bienestar | |
dc.title | Five-year Effects of Chlorhexidine on the In Vitro Durability of Resin/Dentin Interfaces | es_ES |
dc.type | artículo | |
dc.volumen | Vol. 18 | |
sipa.codpersvinculados | 1020227 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Five-year Effects of Chlorhexidine on the In Vitro Durability of Resin.pdf
- Size:
- 122.76 KB
- Format:
- Adobe Portable Document Format
- Description: