Extended MRI-based PET motion correction for cardiac PET/MRI
dc.catalogador | pau | |
dc.contributor.author | Aizaz, Mueez | |
dc.contributor.author | Van der Pol, Jochem A. J. | |
dc.contributor.author | Schneider, Alina | |
dc.contributor.author | Munoz, Camila | |
dc.contributor.author | Holtackers, Robert J. | |
dc.contributor.author | Van Cauteren, Yvonne | |
dc.contributor.author | Van Langen, Herman | |
dc.contributor.author | Meeder, Joan G. | |
dc.contributor.author | Rahel, Braim M. | |
dc.contributor.author | Wierts, Roel | |
dc.contributor.author | Botnar, Rene M. | |
dc.contributor.author | Prieto, Claudia | |
dc.contributor.author | Moonen, Rik P. M. | |
dc.contributor.author | Kooi, M. E. | |
dc.date.accessioned | 2024-04-09T21:30:51Z | |
dc.date.available | 2024-04-09T21:30:51Z | |
dc.date.issued | 2024 | |
dc.date.updated | 2024-04-07T00:04:47Z | |
dc.description.abstract | Purpose: A 2D image navigator (iNAV) based 3D whole-heart sequence has been used to perform MRI and PET non-rigid respiratory motion correction for hybrid PET/MRI. However, only the PET data acquired during the acquisition of the 3D whole-heart MRI is corrected for respiratory motion. This study introduces and evaluates an MRI-based respiratory motion correction method of the complete PET data. Methods Twelve oncology patients scheduled for an additional cardiac 18F-Fluorodeoxyglucose (18F-FDG) PET/MRI and 15 patients with coronary artery disease (CAD) scheduled for cardiac 18F-Choline (18F-FCH) PET/MRI were included. A 2D iNAV recorded the respiratory motion of the myocardium during the 3D whole-heart coronary MR angiography (CMRA) acquisition (~ 10 min). A respiratory belt was used to record the respiratory motion throughout the entire PET/MRI examination (~ 30–90 min). The simultaneously acquired iNAV and respiratory belt signal were used to divide the acquired PET data into 4 bins. The binning was then extended for the complete respiratory belt signal. Data acquired at each bin was reconstructed and combined using iNAV-based motion fields to create a respiratory motion-corrected PET image. Motion-corrected (MC) and non-motion-corrected (NMC) datasets were compared. Gating was also performed to correct cardiac motion. The SUVmax and TBRmax values were calculated for the myocardial wall or a vulnerable coronary plaque for the 18F-FDG and 18F-FCH datasets, respectively. Results A pair-wise comparison showed that the SUVmax and TBRmax values of the motion corrected (MC) datasets were significantly higher than those for the non-motion-corrected (NMC) datasets (8.2 ± 1.0 vs 7.5 ± 1.0, p < 0.01 and 1.9 ± 0.2 vs 1.2 ± 0.2, p < 0.01, respectively). In addition, the SUVmax and TBRmax of the motion corrected and gated (MC_G) reconstructions were also higher than that of the non-motion-corrected but gated (NMC_G) datasets, although for the TBRmax this difference was not statistically significant (9.6 ± 1.3 vs 9.1 ± 1.2, p = 0.02 and 2.6 ± 0.3 vs 2.4 ± 0.3, p = 0.16, respectively). The respiratory motion-correction did not lead to a change in the signal to noise ratio. Conclusion The proposed respiratory motion correction method for hybrid PET/MRI improved the image quality of cardiovascular PET scans by increased SUVmax and TBRmax values while maintaining the signal-to-noise ratio. Trial registration METC162043 registered 01/03/2017. | |
dc.fechaingreso.objetodigital | 2024-04-09 | |
dc.format.extent | 18 páginas | |
dc.fuente.origen | Biomed Central | |
dc.identifier.citation | EJNMMI Physics. 2024 Apr 06;11(1):36 | |
dc.identifier.doi | 10.1186/s40658-024-00637-z | |
dc.identifier.issn | 2197-7364 | |
dc.identifier.uri | https://doi.org/10.1186/s40658-024-00637-z | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/85018 | |
dc.identifier.wosid | WOS:001198026100001 | |
dc.information.autoruc | Instituto de Ingeniería Biológica y Médica; Botnar, Rene M.; 0000-0002-9447-4367; 1015313 | |
dc.information.autoruc | Facultad de Matemáticas; Prieto, Claudia; 0000-0003-4602-2523; 14195 | |
dc.language.iso | en | |
dc.nota.acceso | contenido completo | |
dc.revista | EJNMMI Physics | |
dc.rights | acceso abierto | |
dc.rights.holder | The Author(s) | |
dc.subject.ods | 03 Good health and well-being | |
dc.subject.odspa | 03 Salud y bienestar | |
dc.title | Extended MRI-based PET motion correction for cardiac PET/MRI | |
dc.type | artículo | |
sipa.codpersvinculados | 1015313 | |
sipa.codpersvinculados | 14195 |