• La Universidad
    • Historia
    • Rectoría
    • Autoridades
    • Secretaría General
    • Pastoral UC
    • Organización
    • Hechos y cifras
    • Noticias UC
  • 2011-03-15-13-28-09
  • Facultades
    • Agronomía e Ingeniería Forestal
    • Arquitectura, Diseño y Estudios Urbanos
    • Artes
    • Ciencias Biológicas
    • Ciencias Económicas y Administrativas
    • Ciencias Sociales
    • College
    • Comunicaciones
    • Derecho
    • Educación
    • Filosofía
    • Física
    • Historia, Geografía y Ciencia Política
    • Ingeniería
    • Letras
    • Matemáticas
    • Medicina
    • Química
    • Teología
    • Sede regional Villarrica
  • 2011-03-15-13-28-09
  • Organizaciones vinculadas
  • 2011-03-15-13-28-09
  • Bibliotecas
  • 2011-03-15-13-28-09
  • Mi Portal UC
  • 2011-03-15-13-28-09
  • Correo UC
- Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log in
    Log in
    Have you forgotten your password?
Repository logo
  • Communities & Collections
  • All of DSpace
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log in
    Log in
    Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Aguilar,Víctor"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • No Thumbnail Available
    Item
    Design of partially grouted reinforced masonry shear walls in an earthquake-prone area: Proposal based on the LRFD approach
    (2025) Vargas Carvajal, Laura Andrea; Aguilar,Víctor; Calderón, Sebastián; Araya Letelier, Gerardo Andrés; Sandoval Mandujano, Cristián
    There is a lack of reliability assessment of modern structural masonry design. Hence, a novel reliability-based calibration of the in-plane shear ultimate limit state for partially grouted reinforced masonry shear walls (PGRMSWs) is presented. This calibration allows for the proposal of a load and resistance factor design (LRFD) methodology oriented to in-plane shear design, responding to the need to update the reinforced masonry Chilean code, which is currently based on the allowable stress design (ASD) format. An extensive database of material and assembly tests and numerical research that made this code update proposal feasible are summarized. The reliability-based calibration was performed aiming to define a target reliability index (βT) and the corresponding strength reduction factors (φ) were recommended. A value of βT = 2.5 is defined based on the reliability analysis of representative existing structures against earthquake-induced shear force. The results allow for recommending φ = 0.60 for walls made of multi-perforated clay bricks and φ = 0.70 for walls made of hollow concrete blocks. Additionally, φ = 0.85 and φ = 0.65 are recommended for flexural and axial strength of compression-controlled walls by adapting international standards to Chilean practice. Comparisons of the required horizontal reinforcement between ASD and LRFD methodologies are presented for a 4-story case study building. The results show that the total reinforcement quantities from ASD and LRFD methodologies are similar, which means the proposal does not imply a more restrictive and expensive design; yet, the LRFD proposal provides designs with a uniform reliability level across various load scenarios.

Bibliotecas - Pontificia Universidad Católica de Chile- Dirección oficinas centrales: Av. Vicuña Mackenna 4860. Santiago de Chile.

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback